Detector reset function

gGE Security

Detector reset function

This function is used to reset Smoke Detectors and Zone Troubles. Your system must be Disarmed to use the Reset function.

Step 1

Press [r]-[7]. Resets have now been performed. The FIRE light will go off if the smoke

 

detectors have been reset.

Step 2

If the keypad begins beeping, the reset did not execute properly. Enter your code to silence

 

the keypad. Wait a few minutes and repeat step 2 to attempt another reset. If the keypad still

 

beeps after repeated attempts, please contact your installer.

Setting the system clock

Step 1

Enter [r][9][7].

 

 

 

 

 

Step 2

Enter [master code].

 

 

 

 

Step 3

Enter the “hour code” which must be two (2) digits.

 

 

 

Note: The clock is a 24-hour clock. Refer to the following table.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time

Hour Code

Time

Hour Code

Time

Hour Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12:00 Midnight

00

8:00 AM

08

4:00 PM

16

 

 

 

 

 

 

 

 

 

 

1:00 AM

01

9:00 AM

09

5:00 PM

17

 

 

2:00 AM

02

10:00 AM

10

6:00 PM

18

 

 

3:00 AM

03

11:00 AM

11

7:00 PM

19

 

 

4:00 AM

04

12:00 Noon

12

8:00 PM

20

 

 

 

 

 

 

 

 

 

 

5:00 AM

05

1:00 PM

13

9:00 PM

21

 

 

6:00 AM

06

2:00 PM

14

10:00 PM

22

 

 

7:00 AM

07

3:00 PM

15

11:00 PM

23

Step 4

Enter the

“minutes code” which must be two (2) digits.

 

 

 

Example:

7 minutes after would be entered [0] – [7].

 

 

NX-108/116/124E User manual

Page 14

04/10/04

Page 14
Image 14
GE NX-108/116/124E Detector reset function, Setting the system clock, gGE Security, Enter r97, Enter master code