10
4.0 Technical Data
© Baxi Heating UK Ltd 2012

4.1 Heatmax Combi 24, 28 & 33

Flue Terminal Diameter 100mm
Dimensions Projection 125mm
Outercase Dimensions
Casing Height - 780mm
Overall Height Inc Flue Elbow - 965mm
Casing Width - 450mm
Casing Depth - 345mm
Central Heating Primary Circuit
Pressures bar
Safety Discharge 3
Max Operating 2.5
Min Operating 0.5
Recommended Operating Range 1-2
DHW Circuit bar
Pressures
Max Operating 8
Min Operating 0.15
Flow Rates (24) (28) (33)
l/min l/min l/min
DHW Flow Rate
@ 30o CRise 11.43 13.3 15.7
DHW Flow Rate
@ 35o CRise 9.8 11.5 13.5
Min Working
DHW Flow Rate 2 2 2
Pump
Available Head See graph below
Expansion Vessel - (For Central Heating
only. Integral with appliance) bar
Min Pre-charge Pressure 0.5
(24,28) (33)
Max Capacity of litre litre
CH System 125 155
Primary Water Content
of Boiler (unpressurised) 2.5 2.8
Connections copper tails
Gas Supply - 22mm
Central Heating Flow - 22mm
Central Heating Return - 22mm
Cold Water Mains Inlet - 15mm
DHW Flow - 15mm
Pressure Relief Discharge - 15mm
Temperatures
C.H. Flow Temp (adjustable)
25°C to 80°C max (± 5°C)
D.H.W. Flow Temp (adjustable)
35°C to 60°C max (± 5°C)
dependent upon flow rate
NOxClass 5
0200 400 600 800 1000 1200
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)

Pump - Available Head

0
5
5.5
4.5
Clearances
Above Casing 200 mm Min
Below Casing 150 mm Min*
Front 450 mm Min(For Servicing)
Front 5 mm Min (In Operation)
L.H. Side 5 mm Min
R.H. Side 5 mm Min
*This is MINIMUM recommended dimension. Greater
clearance will aid installation and maintenance.
Heat InputCH (Net) Max Min
24 model kW 20.5 7
28 model kW 24.7 9
33 model kW 28.9 9.7
Heat Output CH (Non-Condensing)
Max Min
24 model kW 20 6.8
28 model kW 24 8.7
33 model kW 28 9.4
Electrical Supply 230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
155W (24&28 model) 160W(33 model)
Electrical Protection
IPX5D
Internal Fuse Rating F2L
Appliance Category CAT I 2H
Inlet Pressure (Natural Gas - G20)
mbar 20
Injector (Natural Gas - G20)
7.5mm (24&28 model) 12mm(33 model)
Appliance Type C13 C33 C53
Heat Output CH (Condensing)
Max Min
24 model kW 21 7.4
28 model kW 25.9 9.5
33 model kW 30.3 10.2
Heat Input DHW (Net) Max
24 model kW 24.7
28 model kW 28.9
33 model kW 34
Heat Output DHW Max
24 model kW 24
28 model kW 28
33 model kW 33
Max Gas Rate (Natural Gas - G20)
(After 10 mins)
24 model m3/h 2.6
28 model m3/h 3.1
33 model m3/h 3.6
Condensate Drain
To accept 21.5mm (3/4in) plastic waste pipe
Heat InputCH (Gross) Max Min
24 model kW 22.7 7.8
28 model kW 27.4 10
33 model kW 32.1 10.8
Heat Input DHW (Gross) Max
24 model kW 27.4
28 model kW 32.1
33 model kW 37.7
External Fuse Rating 3A
Weights (kg) (24/28) (33)
Packaged Boiler Carton 48.6 51
Installation Lift Weight 43.6 46

SAP 2005 Seasonal Efficiency for all

models is 91.1%

This value is used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been
calculated has been certified by 0087.

SEDBUKDeclaration

NOTE:All data in this section are nominal values
and subject to normal production tolerances.
IMPORTANT:Where Low Flow Taps or Fittings are
intended to be used in the DHW system connected it is
strongly recommended that the DHW flow rate DOES
NOT fall below 2.5l/min. This will ensure reliable
operation of the DHW function.