DS-RPC OWNER’S MANUAL
APPENDIX A
__________________________________________________________________ ________________________

75

APPENDIX A

Base

Unit DS71 Host

Module DS71-MD2

Host
Module

DS74

Peripheral

Module

DS73TP

Network

Module
Interface N/A EIA-232,
-12V mark,
+12V space
EIA-232,
-12V mark,
+12V space
V.32bis
(14.4K bps)
MODEM
EIA-232,
-12V mark,
+12V space
Ethernet, IEEE
802.3 complaint,
10Base-T (tw
pair, RJ-45)
Transmission N/A Asynchronous Asynchronous Asynchronous N/a
Protocols N/A N/A N/A N/A PPP, TCP/IP,
ARP & ICMP
Frame Types N/A N/A N/A N/A Ethernet II and
SNAP (802.3)
Handshaking N/A CTS/DTR;
selectable
Xon/Xoff
TD, RD, CD,
MR, CX,
CTS/DTR;
selectable
Xon/Xoff
CTS/DTR;
selectable
Xon/Xoff
N/A
Baud Rate N/A 300, 600,
1200, 2400,
4800, 9600,
19.2K, 38.4K,
57.6K, 76.8K,
or 115.2K
300, 600,
1200, 2400,
4800, 9600,
19.2K, 38.4K,
57.6K, 76.8K,
or 115.2K and
14.4k (internal
modem)
300, 600, 1200,
2400, 4800,
9600, 19.2K,
38.4K, 57.6K,
76.8K, or
115.2K
N/A
Word Size N/A 5, 6, 7, or
8 bits N/A 5, 6, 7, or 8 bits N/A
Stop Bits N/A 1, 1 1/2, or
2 bits N/A 1, 1 1/2, or
2 bits N/A
Parity N/A Even, Odd, or
None N/A Even, Odd, or
None N/A
Buffer Size N/A N/A N/A N/A 256 KB
Mounting
(Optional) Rack Mount
or Desktop N/A N/A N/A N/A
Warranty One year on
parts and
labor
One year on
parts and labor One year on
parts and labor One year on
parts and labor One year on
parts and labor