Wire the burner — R7184B

Wire the burner — R7184B

Electrical Shock Hazard

 

Figure 11. - Typical wiring (R7184B)

 

Electrical shock can cause severe personal in- jury or death.

yDisconnect electrical power before installing or servicing the burner.

yProvide ground wiring to the burner, metal control enclosures and accessories. (This may also be required to aid proper control system operation)

yPerform all wiring in compliance with the National Electric Code ANSI/NFPA 70 (Canada CSA C22.1).

Install the burner and all wiring in accordance with the National

Electrical Code and all applicable local codes or requirements.

Wire the burner in compliance with all instructions provided by the appliance manufacturer. Verify operation of all controls in accordance with the appliance manufacturer’s guidelines.

See Figure 11 for a typical wiring diagram, with R7184 oil primary, for reference purposes only.

Legend

 

 

FD

Fused Disconnect, by others

TR

Ignition transformer

LM

Limit controls, by others

M1

Burner motor

OP

Operating controls, by others

S1

Oil valve

PR

Oil primary control, R7184 typ.

T-T

24-volt thermostat/limit terminals

CC

Flame sensor, cad cell typical

F-F

Cad cell flame sensor terminals

14

Form 6104 BCF23-R05

 

Page 14
Image 14