Beckett CF1400 Adjusting plate initial setting, typical, b Spline nut for securing nozzle line

Models: CF2300 CF1400

1 24
Download 24 pages 57.78 Kb
Page 17
Image 17
Figure 12 – Adjusting plate initial setting, typical

Figure 12 – Adjusting plate initial setting, typical

Legend

b Spline nut for securing nozzle line

c Bottom acorn nut (for head adjustments)

d Top acorn nut (for setting dim. Z only - do not loosen after setting Z)

e Indicator adjusting plate f Secondary adjusting plate g Primary adjusting plate

h Copper oil line from oil valve to nozzle line

Table 4a. CF1400 Initial indicator adjustment plate settings

 

 

Head Position

Damper Position

 

 

 

 

 

 

 

Tube

Approximate

Firing Rate

Approximate

Firing Rate

 

 

Air Damper

 

 

Head Setting

(gph)

(gph)

 

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

0

4.00

0

--

 

 

1

4.50

10

--

 

 

2

5.00

20

4.00

 

 

3

6.00

30

5.00

 

 

4

7.00

40

7.00

 

A

5

7.50

50

8.00

 

 

6

8.00

60

10.00

 

 

7

9.00

70

11.00

 

 

8

9.50

80

--

 

 

9

10.00

90

--

CF1400

 

10

11.00

100

--

 

--

--

110

--

 

 

 

 

--

--

120

--

 

 

0

7.00

0

--

 

 

1

7.50

10

--

 

 

2

8.00

20

--

 

 

3

9.00

30

--

 

 

4

10.00

40

7.00

 

B

5

10.50

50

8.00

 

 

6

11.00

60

10.00

 

 

7

12.00

70

11.00

 

 

8

13.00

80

12.00

 

 

9

13.25

90

12.50

 

 

10

13.60

100

13.00

 

 

--

--

110

13.25

 

 

--

--

120

13.60

 

 

 

 

 

 

Table 4b. CF2300 Initial indicator adjustment plate settings

 

 

Head Position

Damper Position

 

Tube

Approximate

Firing Rate

Approximate

Firing Rate

 

 

Air Damper

 

 

Head Setting

(gph)

(gph)

 

 

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

0

11.0

0

--

 

 

1

12.0

10

7.0

 

 

2

13.0

20

10.0

 

 

3

14.0

30

13.0

 

A

4

15.0

40

14.0

 

5

16.0

50

15.0

 

 

 

 

6

17.0

60

16.0

 

 

7

18.0

70

17.0

CF2300

 

8

19.0

80

18.0

 

9

20.0

90

19.0

 

 

 

 

--

--

100

20.0

 

 

0

12.5

0

--

 

 

1

13.0

10

10.0

 

 

2

14.0

20

13.0

 

 

3

15.0

30

14.0

 

B

4

16.0

40

15.0

 

5

17.0

50

16.0

 

 

 

 

6

18.0

60

17.0

 

 

7

18.5

70

18.0

 

 

8

19.0

80

18.5

 

 

9

20.0

90

19.0

 

 

--

--

100

20.0

 

 

 

 

 

 

Form 6104 BCF23-R05

17

 

Page 17
Image 17
Beckett CF2300 manual Adjusting plate initial setting, typical, a. CF1400 Initial indicator adjustment plate settings