Behringer DSP8024 Digital delay, Level meter, Noise gate, Limiter, Real time analyzer RTA, Memory

Models: DSP8024

1 36
Download 36 pages 40.7 Kb
Page 35
Image 35
Digital delay

 

ULTRA-CURVE PRO DSP8024

 

 

 

Digital delay

 

 

Type

digital stereo delay

 

Maximum delay time

2.5 s, independently adjustable for each channel

Minimum resolution

0.1 msec

 

Delay unit

seconds, meters or feet

 

Level meter

 

 

Type

Digital level meter with simultaneous graphical display of peak and RMS values

Attack/Decay (RMS)

60 dB/s

 

Attack (Peak)

1 sample

 

Decay (Peak)

20 dB/s

 

Noise gate

 

 

Type

digital IRC (Interactive Ratio Control)

Threshold

variable from -44 to -96 dB in steps of 1 dB

Attack/Release

processor controlled, program dependent

Limiter

 

 

Type

digital IGC (Interactive Gain Control)

Threshold

variable from 0 to -36 dB in steps of 1 dB

Release

500 to 5000 ms in steps of 250 ms

Real time analyzer (RTA)

 

 

Type

digital 1/3 octave analyzer

 

Frequency range

31 filters on ISO center frequencies, from 20 Hz to 20 kHz

Detectors

peak or RMS

 

Decay

variable 1 s, 250 msec, 65 msec or 15 msec (per 20 dB)

Sine wave generator

frequency adjustable from 20 Hz to 20 kHz in steps of 1/60 octave, gain adjustable

 

from 0 to -48 dB in steps of 0.5 dB

Noise generator

white or pink characteristic, gain adjustable from 0 to -48 dB in steps of 0.5 dB

Display

 

 

Type

240 x 64 dot matrix, liquid crystal display (LCD)

Backlight

LED array

 

Contras

adjustable

 

Memory

 

 

EQ programs

100 memory locations, capable of storing all relevant settings for GEQ, PEQ,

 

FB D and DELAY in addition to a program name with 12 characters

RTA measurements

10 memory locations

 

Password protection

2 levels, memory protect or security lock, both protected with an alphanumerical

 

12 digit password

 

Power supply

 

 

Operating voltage

USA/Canada

120 V ~, 60 Hz

 

U.K./Australia

240 V ~, 50 Hz

 

Europe

230 V ~, 50 Hz

 

general export model

100 - 120 V ~, 200 - 240 V ~, 50 - 60 Hz

Power consumption

max. 30 W

 

Fuse rating

100 - 120 V ~: T 630 mA H

 

200 - 240 V ~: T 315 mA H

Mains connection

standard IEC receptacle

 

Battery

Lithium CR 2032, 3 V, 180 mAh

Battery life

3 years, typical

 

Physical

 

 

Dimensions (H * W * D)

3 1/2" (89 mm) * 19" (482.6 mm) *12" (304.8 mm)

Net weight

app. 5 kg

 

Shipping weight

app. 6.6 kg

 

BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to existing products without prior notice. Specifications and appearance may differ from those listed or illustrated.

8. TECHNICAL SPECIFICATIONS

35

Page 35
Image 35
Behringer DSP8024 Digital delay, Level meter, Noise gate, Limiter, Real time analyzer RTA, Display, Memory, Power supply