22EUROLIGHT LC2412 User Manual
9.3.2Sub D connections (Analog Control)
The following table shows the cable layout of the individual contacts of the sub D connection for analog dimmer control.
Pin No. | Cons. channel |
Pin 1 | Channel 1 |
Pin 2 | Channel 2 |
Pin 3 | Channel 3 |
Pin 4 | Channel 4 |
Pin 5 | Channel 5 |
Pin 6 | Channel 6 |
Pin 7 | Channel 7 |
Pin 8 | Channel 8 |
Pin 9 | Channel 9 |
Pin 10 | Channel 10 |
Pin 11 | Channel 11 |
Pin 12 | Channel 12 |
Pin 13 | Special 1 |
Pin 14 | Special 2 |
Pin 15 | Ground |
Table. 9.1: Cable layout of the sub D connection
9.3.3 MIDI connection
Coonect to other MIDI equipment or another EUROLIGHT LC2412 by using common MIDI cables. The cables should never be longer than 15 m (45 ft).
9.3.4 Audio connections
To control the EUROLIGHT LC2412 via an audio signal, please use a mono jack connector with standard configuration.
Unbalanced ¼" TS connector
strain relief clamp sleeve
tip
sleeve (ground/shield)
tip
(signal)
Fig. 9.2: 1/4" TS connector for audio signals
9.3.5 Footswitch
You can use a footswitch to trigger chase steps. This way, both of your hands remain free, letting you control additional settings of your LC2412.
¼" TS footswitch connector
strain relief clamp sleeve
tip
sleeve
pole 1/ground
tip pole 2
The footswitch connects both poles momentarily
Fig. 9.3: Footswitch connector
As long as a footswitch is kept pressed, the connection of both contacts is closed. Therefore, a footswitch does not act as a switch.
9.4 Rack mounting
Your EUROLIGHT LC2412 is
◊Always make sure that your LC2412 is provided with sufficient ventilation to avoid overheating of the unit!