TESTS COMMON TO MORE THAN ONE COMPLAINT

1.

Discharge plugged or restricted

If build-up still NOT OK or temp. above 32 deg. F, replace air

Connect temporary discharge line from comp. discharge port

 

dryer purge valve assembly.

 

to supply res. & re-check build-up. If build-up OK replace

4.

Air system leakage

 

plugged discharge line. If build-up NOT OK go to next cause.

Build system pressure to governor cut-out, wait 2 minutes for

2.

Air pressure trapped between governor and compressor

 

dryer purge completion. Note pressures on dash gauges

Verify safety valve operation then remove or disconnect

 

then watch dash gauges for 2 minutes. Leakage not to

 

governor from compressor & check build-up.

 

exceed 2 psi in 2 mins. for truck, bus, tractor (no trailer).

If build-up OK, repair or replace governor or line between governor

If leakage NOT OK on gauges, find leak(s) in service and park

 

and compressor.

 

system and repair. Retest and if system purge air dryer in use

If build-up NOT OK repair or replace compressor.

 

and still not OK repair or replace dryer.

3.

Blow Leakage at Air Dryer Exhaust

If leakage OK on gauges, drain air from supply reservoir,

Drain all air from supply reservoir then remove control air line

 

remove drain cock and install air gauge. Build system air in

 

from air dryer, plug line and plug control port in air dryer. Re-

 

supply reservoir and note leakage. If OK continue checking.

 

check build-up.

 

If NOT OK find leaks and repair.

If build-up OK, repair or replace governor or line between

5.

Discharge line leakage

 

governor and air dryer.

Soap cover on flex discharge line, if leakage noted replace

If build-up NOT OK, and below 32 deg. F, turn ignition ON and

 

line.

 

allow heater to warm air dryer then check build-up. If NOT OK,

Soap fittings to check leakage, tighten as needed.

 

remove wire (connector or terminal) from air dryer. Using test

 

 

 

light, check wire end or terminal for battery voltage with vehicle

 

 

 

ignition ON. If voltage OK, repair or replace air dryer heater

 

 

 

and thermostat. If voltage NOT OK, repair or replace the

 

 

 

vehicle wire connected to air dryer. Retest build-up.

 

 

IMPORTANT: The Complaints, Causes and Remedies presented here should not be considered as the only situations possible. They are only meant to represent the most commonly encountered. It may be necessary to perform additional trouble shooting using the more detailed information presented in service manuals for the specific components.

27

Page 27
Image 27
BENDIX BW1811 manual Tests Common to More than ONE Complaint, Discharge plugged or restricted