DRM/AD-IS®AIR DRYER TROUBLESHOOTING CHART (Continued)

SYMPTOMS

CAUSE

REMEDY

3. Safety valve on air dryer

A. Defective AD-IS®air

A. Test to determine if air is passing through check

“popping off” or

dryer delivery check

valve. Repair or replace. Refer to Symptom 1,

exhausting air.

valve.

Remedy B.

 

 

 

 

 

 

B. System pressure too

B. Test with accurate gauge. Replace governor if

 

 

high (>135 p.s.i.)

necessary.

 

 

 

 

 

 

C. Excessive pressure

C. Increase volume in discharge line. This can be

 

 

pulsations from

accomplished by adding a 90 cubic inch (or

 

 

compressor. (Typical

larger) reservoir between the compressor and the

 

 

single cylinder type).

AD-IS®air dryer.

 

 

 

 

 

 

D. Safety valve setting too

D. Replace safety valve.

 

 

low (<150 p.s.i.)

 

 

 

 

4. Constant exhaust of air

A. Air dryer purge valve

A. With compressor loaded, apply soap solution

at air dryer purge valve

leaking excessively.

on purge valve exhaust, to test for excessive

exhaust or unable to

 

leakage. Repair or replace purge valve as

build system pressure.

 

necessary.

(Charge mode.)

 

 

 

 

 

 

 

 

B. Purge valve frozen open

B. Refer to paragraph 5 of Operation and Leakage

 

 

- faulty heater and

Tests for heater and thermostat test.

 

 

thermostat, wiring,

 

 

 

blown fuse.

 

 

 

 

 

 

 

C. Defective AD-IS®air

C. Refer to Symptom 1, Remedy B.

 

 

dryer delivery check

 

 

 

valve.

 

 

 

 

 

 

 

D. Leaking Turbo Cutoff

D. Repair or replace purge valve assembly.

 

 

valve.

 

 

 

 

 

 

 

E. Defective governor.

E. Check governor at both “cut-in” and “cut-out”

 

 

 

position for (i) proper pressures and (ii)

 

 

 

excessive leakage at fittings and exhaust.

 

 

 

 

 

 

F. Leaking purge valve

F. Repair or replace purge valve assembly.

 

 

control piston quad-ring.

 

 

 

 

 

12

Page 12
Image 12
BENDIX BW1948 manual DRM/AD-ISAIR Dryer Troubleshooting Chart