BenQ MX505 Indicators, Light Status & Description Power events, Lamp events, Thermal events

Models: MX505 MS504

1 55
Download 55 pages 15.82 Kb
Page 49
Image 49

Indicators

Light

Status & Description

Power events

Orange

Off

Off

Stand-by mode

Green

Off

Off

Powering up

Flashing

 

 

 

Green

Off

Off

Normal operation

Orange

Off

Off

Normal power-down cooling

Flashing

 

 

 

Red

Off

Off

Download

Green

Off

Red

CW start fail

Red Flashing

Off

Off

Scaler shutdown fail (data abort)

 

 

Lamp events

 

 

 

 

Off

Off

Red

Lamp1 error in normal operation

Off

Off

Orange

Lamp is not lit up

Flashing

 

 

 

Green

Off

Red

Lamp usage time exceeded

 

 

Thermal events

Red

Red

Off

Fan 1 error (the actual fan speed is +25% outside

the desired speed)

 

 

 

Red

Red

Off

Fan 2 error (the actual fan speed is +25% outside

Flashing

the desired speed)

 

 

Green

Red

Off

Temperature 1 error (over limited temperature)

Maintenance 49

Page 49
Image 49
BenQ MX505, MS504 user manual Indicators, Light Status & Description Power events, Lamp events, Thermal events