Electrical connection
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is about 1W for 5 gas burner version or 2W for 6 gas burners version.
WARNING: Electrical Grounding Instructions: This appliance is equipped with a
Wiring diagrams | Wiring diagram description | |
For hotplate model A see Fig. 11. | 1. | Cable terminal |
For hotplate model B see Fig. 12. | 2. | Ignition switch |
| 3. | Spark generator |
| 4. | Ignition spark |
| L. Black | |
| N. White | |
| T. Green (earth) |
Room ventilation – Location and venting.
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the national standards in force.
Conversion to different types of gas
Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described in fig. 5.
-CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: To change the nozzles of the burners use the following procedure:
Lift up the burners and unscrew the nozzles ( Fig. 7) using an adjustable spanner of 7 mm and change the nozzles with those designed for the new gas supply according to the information given in TABLE A shown below.
TABLE A: Adapting to different types of gas
Burner | Position | Inj. size | Gas | Pressure | Max Rate |
| Min Rate | |||
|
| 1/100mm | Type | [i.w.c.] | [BTU/h] |
| [W] | [BTU/h] | [W] | [1/100mm] |
Auxiliary | Front R | 0,90 | NG | 4” | 3400 |
| 996 | 900 | 264 | Regulated |
|
| 0,54 | LP(Propane) | 11” | 3400 |
| 996 | 900 | 264 | 0,29 |
Rear L | 1,18 | NG | 4” | 6100 |
| 1787 | 1500 | 439 | Regulated | |
| Rear R | 0,70 | LP(Propane) | 11” | 6100 |
| 1787 | 1500 | 439 | 0,37 |
Rapid | Front L | 1,55 | NG | 4” | 10400 |
| 3047 | 3700 | 1084 | Regulated |
|
| 0,92 | LP(Propane) | 11” | 10400 |
| 3047 | 3700 | 1084 | 0,58 |
| Centre Inner | 0,80 | NG | 4” | 2800 |
| 820 | 900 | 264 | Regulated |
Dual |
| 0,49 | LP(Propane) | 11” | 2800 |
| 820 | 900 | 264 | 0,29 |
burner | Centre Outer | N°2 x 1,15 | NG | 4” | 12000 |
| 3516 | 5300 | 1553 | Regulated |
|
| N°2 x 0,70 | LP(Propane) | 11” | 12000 |
| 3516 | 5300 | 1553 | 0,73 |
Burner | Position | Inj. size | Gas | Pressure | Max Rate |
| Min Rate | |||
|
| 1/100mm | Type | [i.w.c.] | [BTU/h] |
| [W] | [BTU/h] | [W] | [1/100mm] |
Auxiliary | Front R | 0,90 | NG | 4” | 3400 |
| 996 | 900 | 264 | Regulated |
|
| 0,54 | LP(Propane) | 11” | 3400 |
| 996 | 900 | 264 | 0,29 |
Rear L & C | 1,18 | NG | 4” | 6100 |
| 1787 | 1500 | 439 | Regulated | |
| Front C | 0,70 | LP(Propane) | 11” | 6100 |
| 1787 | 1500 | 439 | 0,37 |
Rapid | Front L | 1,55 | NG | 4” | 10400 |
| 3047 | 3700 | 1084 | Regulated |
|
| 0,92 | LP(Propane) | 11” | 10400 |
| 3047 | 3700 | 1084 | 0,58 |
| Centre Inner | 0,80 | NG | 4” | 2800 |
| 820 | 900 | 264 | Regulated |
Dual |
| 0,49 | LP(Propane) | 11” | 2800 |
| 820 | 900 | 264 | 0,29 |
burner | Centre Outer | N°2 x 1,15 | NG | 4” | 12000 |
| 3516 | 5300 | 1553 | Regulated |
|
| N°2 x 0,70 | LP(Propane) | 11” | 12000 |
| 3516 | 5300 | 1553 | 0,73 |
CAUTION: save the orifices removed from the appliance for future use