4)Loose strain relief by unscrewing the two strain relief's screws as in diagram.

5) Remove damaged supply cord set by taking off the 4 electrical connection screws (block L1, N, L2 and Ground screw, see diagram)

6) Insert the new supply cord set in the strain relief and lock it with two strain relief's screws in suitable position.

7) Fix well the ring terminals G, L1, N, L2 of the new supply cord set as shown in diagram with its 4 screws

8) Re‐install the back enclosure panel with 6 screws

9) Slide the appliance back into its proper location

10) Re‐connect the appliance to the electrical power.

ELECTRICAL GROUNDING

This appliance is equipped with a four‐prong plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove the grounding prong from this plug.