f)The appliance must be isolated from the gas supply piping system by closing its individuai manual
3.Flexible Connections:
a)If the unit is to be installed with flexible couplings and/or quick disconnect fittings, the installer must use a
b)In Massachusetts: The unit must be installed with a 36"
c)In Canada: CAN
CAUTlON: Leak testing of the appliance shall be conducted according to the manufacturer's instructions. Before placing the oven into operation, always check for leaks with a soapy water solution or other acceptable method. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS!
A 2”( 5 cm)
B 3”(7,6 cm)
D 8”(20,3 cm)
A
An
PERFORMANCE CHECKLlST
All burners are tested before leaving the factory. There are no adjustments for the burners if connected according to the information on the rating plate. Check each burner for proper operations. Flames should be blue in all settings. If service is required, contact your dealer for the name of their authorized service agency. Gas conversions and initial installation are not the responsibility of the manufacturer.
The installer should carry out the following performance checks. Refer to instructions below.
1.Check surface burner ignition.
2.Check air shutter adjustment (only for oven and broiler burner)- sharp blue flame, no yellow tipping, sooting or flame lifting
3.Check low flame adjustment
4.Check broiler and oven ignition - all burner ports.
5.Check for gas leaks (odors) at all gas connections.
6.Check oven bake and convection bake function.
10