EXTERIOR OR IN-LINE BLOWER SELECTION

EXTERIOR OR IN-LINE BLOWER SELECTION

CAUTION: Either an exterior blower or in-line blower may be used with this hood. The U102E hood must be installed with blower models EB6, EB9, EB12, EB15, ILB3, ILB6, ILB9, or ILB11 only. Other Blowers cannot be substituted (Blowers sold separately).

The blower must be UL listed for Canadian and U.S. use, and evaluated for use with solid state speed control, rated 120V, 60 Hz, 6.0 A max.

INSTALL THE DUCTWORK

NOTE: To reduce the risk of fire, use only metal ductwork.

1.Choose the location where the Exterior or In-Line Blower will be mounted. See illustrations below for mounting location suggestions and restrictions.

2.A straight, short duct run will allow the hood to perform most efficiently.

3.Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with long duct runs.

4.After the Exterior or In-Line Blower has been installed, connect round metal ductwork and work back towards the hood location. Use duct tape to seal joints between ductwork sections.

5.An 8” round to 10” round transition (Model 414) is required. For best air performance, install the transition as close to the range hood as possible.

EXTERIOR BLOWER

SUGGESTED MOUNTING LOCATIONS

OK

OK

CAUTION: MAY NOT FIT

UNDER EAVES OF SINGLE

STORY HOMES

EXTERIOR

10” ROUND

8” TO 10”

BLOWER

DUCT

ROUND

 

 

TRANSITION

8” ROUND

DUCT

EXTERIOR

BLOWER

HOOD

22-1/2”

 

ABOVE

10”

COOKING

SURFACE

ROUND

 

DUCT

 

8” ROUND

 

ELBOW

- 10 -