EXTERIOR OR IN-LINE BLOWER SELECTION
CAUTION: Either an exterior blower or
The blower must be UL listed for Canadian and U.S. use, and evaluated for use with solid state speed control, rated 120V, 60 Hz, 6.0 A max.
INSTALL THE DUCTWORK
EXTERIOR BLOWER
NOTE: To reduce the risk of fire, use only metal ductwork.
1.Choose the location where the Exterior or
2.A straight, short duct run will allow the hood to perform most efficiently.
3.Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with long duct runs.
4.After the Exterior or
5.An 8” round to 10” round transition (Model 414) is required. For best air performance, install the transition as close to the range hood as possible.
DUCTWORK ON THE CEILING
10” ROUND | EXTERIOR |
DUCT | BLOWER |
| |
| 8” TO 10” |
| ROUND |
| TRANSITION |
8” ROUND
DUCT
HOOD
SUGGESTED MOUNTING LOCATIONS
OK
OK
CAUTION: MAY NOT FIT
UNDER EAVES OF SINGLE
STORY HOMES
DUCTWORK ON THE WALL
8” TO 10”
ROUND
TRANSITION
EXTERIOR
BLOWER
10”
HOODROUND DUCT
COOKING SURFACE |
|