WIRING

BLOWER CONNECTION AT

HOOD (DUCTWORK ON THE CEILING)

CAUTION: All electrical wiring should be done by a qualified person (s) in

accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring.

Do not turn power on at service panel until all wires have been connected.

Blower connection at hood:

CONNECT: WHITE-TO-WHITE, RED-TO-BLACK, GREEN-TO-GROUND.

Exterior or In-Line

blower

BOX MARKED “MOTOR CONNECTION”

1.

Run conductors (2-wire plus ground) from

 

the Exterior or In-Line Blower to the hood’s

 

wiring box marked “motor connection”.

 

See Fig. 1 if the ductwork is placed on the

 

ceiling; see Fig. 2 if the ductwork is placed

 

on the wall.

2.

Remove the cover from the wiring box.

 

Fig. 1 or 2.

3.

Secure the conduit to the wiring box

 

through a conduit connector. Fig.1 or 2

FIG. 1

BLOWER CONNECTION AT

HOOD (DUCTWORK ON THE WALL)

4.

Make electrical connections at the hood.

 

Connect white-to-white, red-to-blackand

 

green-to-ground. Fig.1 or 2.

5.

Replace the wiring box cover and screws.

 

Make sure wires are not pinched between

 

the cover and box.

Exterior or In-line blower connection:

1.Make electrical connections at the exterior or in-line blower (see instructions provided with the exterior or in-line blower).

CONNECT: WHITE-TO-WHITE, RED-TO-BLACK, GREEN-TO-GROUND.

Exterior or In-

Line blower

BOX MARKED “MOTOR CONNECTION”

FIG. 2

- 10 -

Page 10
Image 10
Best WM24E manual Wiring, Exterior or In-line blower connection