Cleaning the upper tank continued

Maintenance and care

Cleaning the upper tank continued

4.The inner cyclone and filtration disk may be washed using a mild detergent. Be sure it is completely dry before reassem- bling or damage to your unit may result.

5.Once cleaning is completed, reassemble the filtration disk over the inner cyclone by sliding it straight down on the top of the inner cyclone and turning left. Be sure to line up the tabs when reassembling for proper installation.

6.To replace the inner cyclone, slide it into the upper housing. Be sure to line up the inner cyclone by ensuring tabs on filtration disk are positioned toward the front of the unit. Push the inner cyclone in and rotate it to the right until the locking tabs stop the rotation.

Troubleshooting

Vacuum cleaner won’t run

Possible causes

1.Vacuum cleaner is not plugged in

2.Damaged power cord

5.6.

Troubleshooting WARNING:

To reduce the risk of electric shock, turn power OFF and disconnect plug from electrical outlet before performing maintenance or troubleshooting.

Remedies

1.Check electrical plug

2.Replace as necessary by an authorized service representative.

Vacuum cleaner and tools won’t pick up dirt

Possible causes

Remedies

1.

Incorrect height adjustment

1.

Adjust powerfoot to correct height

2.

Hose not attached to suction opening

2.

Firmly push hose wand into hose wand base

3.

Twist 'n Snap hose not securely attached

3.

Make sure Twist 'n Snap hose is snapped into locked position

4.

Crack or hole in hose

4.

Check hose and replace if needed

5.

Broken or worn drive belt

5.

Replace drive belt, see pages 10-11

6.

Rotating floor brush bristles worn

6.

Replace brush

7.

Rotating floor brush jammed

7.

Remove brush and clean debris from brush ends

8.

Clog in vacuum

8.

Clear clogs, see page 12.

9.

Dirt container full

9.

Empty dirt container

10.

Dirt container not installed properly

10.

Position correctly and lock in place

11.

Filters are dirty

11.

Check pre-motor and post-motor filters

12.

Pet TurboBrush™ Tool is clogged or

12.

See pages 11-12 for Maintaining

 

debris is wrapped around the brush roll

 

Pet TurboBrush™ Tool

Vacuum cleaner is difficult to push

 

 

Possible causes

Remedies

1. Incorrect height setting

1. Adjust powerfoot to correct height setting

 