Replace drive belt continued

Maintenance and care

Replace drive belt continued

3.Place new drive belt over motor pulley and loop other end over rotating floor brush in the space between the bristles.

NOTE: It is important that you use only genuine BISSELL replacement belts. Generic belts may not meet the exact specifications required to keep your vacuum operating at its peak performance. The use of unbranded belts could lead to early failure of the vacuum and could void your warranty.

4.Pull the rotating floor brush firmly into position, stretching the drive belt, and place ends of rotating floor brush down into the slots on sides as shown. Alignment of brush ends in slots may be necessary to fully insert the brush.

3.

Motor

Pulley

5.Turn rotating floor brush by hand several times in the direction of motor pulley. If properly installed, drive belt will center itself on rotating brush crown.

6.Insert front edge of brush cover and rotate into place. Snap the three latches and replace the two screws.

Replacing lightbulb

1.Unplug the vacuum from electrical outlet.

2.Using a screwdriver, first remove 2 screws on either side of lens and pull out to remove the lens.

3.Remove the bulb from the socket by grasping the bulb and pulling gently. Install the new bulb by pushing it gently into the socket until the bulb snaps into place.

4.Reposition the lens place cover back over headlight and reinsert 2 screws.

Maintaining Pet TurboBrushTool

The Pet TurboBrush™ Tool should be checked regularly for clogs or debris wrapping around the brush.

1.Remove tool from hose or front of vacuum.

2.Twist collar so opening is at the top and lift top cover to remove.

2.

3.

4.

2.

11

w w w . b i s s e l l . c o m

Page 11
Image 11
Bissell 10N6-F Replace drive belt continued, Replacing lightbulb, Maintaining Pet TurboBrush Tool, Maintenance and care