Compaq 386 manual Advanced Diagnostics Error Codes

Models: 386

1 276
Download 276 pages 50.35 Kb
Page 104
Image 104

5-12 Chapter 5, Error Messages and Codes

Table 5-2. Advanced Diagnostics Error Codes Continued

Error

 

Recommended

Code

Description

Action

Security Lock Test

 

 

 

 

 

315-01

Security lock inoperative.

The following steps apply to error codes 315-xx:

 

 

 

 

315-02

Security lock stuck in locked position.

1.

Verify the security lock cable connection.

 

 

2.

Replace the security lock and retest.

Parallel Printer Test

 

 

401-01

Printer failed or not connected.

The following steps apply to error codes 401-xx

 

 

through 498-xx:

402-01

Printer data register failed.

1.

If a printer is connected, be sure it is turned ON and in

 

 

402-02

Printer control register failed.

 

the ONLINE mode.

 

 

 

402-03

Printer data and control register failed.

 

2.

Check the switch settings and jumper positions on

402-04

Printer loopback failed.

 

the multipurpose fixed disk controller board (see

 

 

 

Chapter 8).

402-05

Printer loopback and data failed.

 

3.

Replace the printer and/or the printer cable and retest.

402-06

Printer loopback and control

4.

Replace the multipurpose fixed disk drive controller

 

register failed.

 

board.

 

 

5.

Replace the system board and retest.

402-07

Printer loopback, data and control

 

 

 

register failed.

 

 

402-08

Printer interrupt test failed.

 

 

 

 

 

 

402-09

Printer interrupt and data

 

 

 

register failed.

 

 

402-10

Printer interrupt and control

 

 

 

register failed.

 

 

402-11

Printer interrupt, data and control

 

 

 

register failed.

 

 

402-12

Printer interrupt, and loopback failed.

 

 

 

 

 

 

Continued...

Addendum 108431-001 (11-88) to Manual No. 108033-003

Page 104
Image 104
Compaq 386 manual Advanced Diagnostics Error Codes