5-14 Chapter 5, Error Messages and Codes

Table 5-2. Advanced Diagnostics Error Codes Continued

Error

 

Recommended

Code

Description

Action

508-01

Video 320 × 200 mode color set 0 test

The following steps apply to error codes 501-xx

 

failed.

through 516-xx:

509-01

Video 320 × 200 mode color set 1 test

1. Replace the monitor and retest.

 

failed.

2. Replace the video display controller board and retest.

 

 

3. Replace the system board and retest.

510-01

Video 640 × 200 mode test failed.

 

 

 

 

511-01

Video screen memory page

 

 

test failed.

 

512-01

Video gray scale test failed.

 

 

 

 

514-01

Video white screen test failed.

 

 

 

 

516-01

Video noise pattern test failed.

 

517-01

Lightpen text mode test

The following steps apply for error codes 517-xx:

 

failed–no response.

1. Replace the lightpen and retest.

517-02

Lightpen text mode test

2. Replace the video display controller board and retest.

 

failed–invalid response.

3. Replace the system board and retest.

517-03

Lightpen medium resolution mode test

 

 

failed–no response.

 

517-04

Lightpen medium resolution mode test

 

 

failed–invalid response.

 

Continued...

Addendum 108431-001 (11-88) to Manual No. 108033-003