5-10 Chapter 5, Error Messages and Codes

Table 5-2. Advanced Diagnostics Error Codes Continued

Error

 

Recommended

Code

Description

Action

Memory Test

 

 

 

 

 

210-xx

Incrementing pattern test.

Replace the memory board and retest for 210 and 211

 

 

error codes.

210-01

Data read from block did not match

 

 

data written.

 

 

 

 

210-02

Scan of test block prior to testing.

 

 

 

 

210-05

Inverted pattern compare, but RAM

 

 

was correct.

 

210-10

Mapping LIM block, LIM page

 

 

not present.

 

211-xx

Random pattern test.

 

211-01

Test failed.

 

 

 

 

211-02

Error while saving test block.

 

 

 

 

211-03

Error while restoring test block.

 

 

 

 

211-04

Insufficient memory to perform test.

 

211-05

Inverted pattern compare, but RAM

 

 

was correct.

 

Keyboard Test

 

 

 

 

301-01

Keyboard short test, 8042 self

The following steps apply to error codes 301-xx

 

test failed.

through 304-xx:

301-02

Keyboard short test, interface

1. Check the keyboard connection. If disconnected, turn

 

test failed.

off the computer and connect the keyboard.

301-03

Keyboard short test, echo test failed.

2. Replace the keyboard and retest.

3. Replace the system board and retest.

 

 

301-04

Keyboard short test.

 

 

 

 

302-01

Keyboard long test failed.

 

 

 

 

Continued...

Addendum 108431-001 (11-88) to Manual No. 108033-003

Page 102
Image 102
Compaq 386 manual Advanced Diagnostics Error Codes