5-8 Chapter 5, Error Messages and Codes

Table 5-2. Advanced Diagnostics Error Codes Continued

Error

 

Recommended

Code

Description

Action

111-01

Refresh detect test failed.

Replace the system board and retest for error codes

 

 

103-xx through 113-xx.

112-01

Speed test slow mode out of range.

 

 

 

 

 

 

112-02

Speed test mixed mode out of range.

 

 

 

 

 

 

112-03

Speed test fast mode out of range.

 

 

 

 

 

 

112-04

Speed test unable to enter slow mode.

 

 

 

 

 

 

112-05

Speed test unable to enter mixed mode.

 

 

 

 

 

 

112-06

Speed test unable to enter fast mode.

 

 

112-07

Speed test system error.

 

 

 

 

 

 

112-08

Speed test unable to enter auto mode.

 

 

 

 

 

 

112-09

Speed test unable to enter high mode.

 

 

 

 

 

 

112-10

Speed test high mode out of range.

 

 

112-11

Speed test auto mode out of range.

 

 

 

 

 

 

112-12

Speed test variable speed mode

 

 

 

inoperative.

 

 

113-01

Protected mode test failed.

 

 

 

 

 

 

114-01

Speaker test failed.

1.

Verify the speaker connection.

 

 

2.

Replace the speaker and retest.

 

 

3.

Replace the system board and retest.

199-00

Installed devices test failed.

1.

Check system configuration.

 

 

2.

Verify cable connection.

 

 

3.

Check switch settings.

 

 

4.

Run SETUP.

 

 

5.

Replace the system board and retest.

Continued...

Addendum 108431-001 (11-88) to Manual No. 108033-003

Page 100
Image 100
Compaq 386 manual Advanced Diagnostics Error Codes