Table 5-2. Advanced Diagnostics Error Codes Continued

Error

 

Recommended

Code

Description

Action

105-07

Port 61 bit 3 not at one.

Replace the system board and retest for error codes

 

 

103-xx through 113-xx.

105-08

Port 61 bit 1 not at one.

 

 

 

 

105-09

Port 61 bit 0 not at one.

 

 

 

 

105-10

Port 61 I/O test failed.

 

 

 

 

105-11

Port 61 bit 7 not at zero.

 

 

 

 

105-12

Port 61 bit 2 not at zero.

 

 

 

 

105-13

No interrupt generated by

 

 

failsafe timer.

 

105-14

NMI not triggered by failsafe timer.

 

 

 

 

106-01

Keyboard controller self-test failed.

 

 

 

 

107-01

CMOS RAM test failed.

 

 

 

 

108-02

CMOS interrupt test failed.

 

108-03

CMOS interrupt test, CMOS not

 

 

properly initialized.

 

109-01

CMOS clock load data test failed.

 

 

 

 

109-02

CMOS clock rollover test failed.

 

 

 

 

109-03

CMOS clock test, CMOS not

 

 

properly initialized.

 

110-01

Programmable timer load data

 

 

test failed.

 

110-02

Programmable timer dynamic

 

 

test failed.

 

110-03

Programmable timer #2 load data

 

 

test failed.

 