Maintenance and Service Guide

5-25

Table 5-2. Advanced Diagnostics Error Codes Continued

Error

 

Recommended

Code

Description

Action

-xx

 

The following steps apply to error codes 1700-xx

 

 

through 1799-xx:

61

Failed uncorrectable ECC* error.

1. Run SETUP.

 

 

62

Failed correctable ECC* error.

2. Check the switch settings and jumper positions on the

 

 

63

Failed soft error rate.

controller board and retest (see Chapter 8).

65

Exceeded maximum bad sector

3. Replace the fixed disk drive signal and power cables

 

per track.

and retest.

 

 

4. Replace the controller board and retest.

66

Failed initial drive parameter.

5. Replace the fixed disk drive and retest.

67

Failed to write long.

6. Replace the system board and retest.

68Failed to read long.

69Failed to read drive size from controller.

70Failed translate mode.

71Failed nontranslated mode.

72Bad track limit exceeded.

73Previously exceeded bad track limit. *Error Correction Code

Continued...

Addendum 108431-001 (11-88) to Manual No. 108033-003

Page 117
Image 117
Compaq 386 manual Advanced Diagnostics Error Codes