Maintenance and care

Machine storage

1.Wrap power cord around Quick Release Cord Wrapon side of PowerEase.

2.Wipe all surfaces with a soft cloth. Store cleaner

upright in a protected, dry area.

NOTE: You may have cleaning solution remaining in the solution tank. You may store your PowerEase this way for the next cleaning task, but never keep soiled solution in the col- lection tank.

WARNING:

To reduce the risk of injury from moving parts and/or electrical shock, turn power switch OFF and disconnect plug from electrical outlet before performing maintenance or troubleshooting checks.

To install the replacement brush belt

1.Turn the machine off and unplug from wall outlet.

2.Remove solution and collection tanks.

3.Lie machine down to access the bottom of the machine.

4.

With a Phillips head screwdriver,

unscrew the

 

brush cover and remove.

 

5.Remove the brush end cap and remove belt from brush.

6.Brush can now be removed.

7.Belt can be removed by sliding off the motor pulley.

8.Clean or replace belt. Attach belt to motor pulley and brush, insert brush into right side end cap.

9.Reattach the left end cap and slide brush back into place.

10.Replace the brush cover and screw into place.

CAUTION:

Do not store unit where freezing may occur. Damage to internal components may result.