15
Performing repairs may expose voltage sources, moving parts or
compressed air sources, personal injury may occur. Maintenance
other than that recommended in the “Troubleshooting” section of this manual is
not recommended and should be performed by trained service personnel.
PROBLEM CAUSE CORRECTION
Compressor does not turn
off when compressor
reaches "cut-out" pressure.
Pressure switch "cut-out"
too high.
Set Auto/On/Off switch to
the "OFF" position, if the
unit does not shut off contact
a Trained Service Technician.
Contact a Trained Service
Technician.
Excessive tank
pressure - safety
valve pops off.
Tube fittings are not tight
enough.
Using a soapy water solution
check all exposed fittings for
leaks. If needed reseal
fittings with pipe sealant
tape and retighten securely.
Do Not Overtighten. If
leaks continue contact a
Trained Service Technician.
Air leaks at
fittings.
Air leaks in air
tank or at air
tank welds.
Defective air tank. Air tank must be replaced.
Do not repair the leak.
Do not drill into, weld or
otherwise modify air tank
or it will weaken. The tank
can rupture or explode.
TROUBLESHOOTING
Low voltage. Extension cord is wrong
length or gauge. Check
extension cord.
Thermal
overload
protector cuts
out repeatedly. Improper ventilation/
temperature too high.
Operate compressor in a
well ventilated area.
Defective check valve. Contact a Trained Service
Technician.
Defective valves. Contact a Trained Service
Technician.
641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 15