641915-00,FSCP200 Compressor

3/14/06 7:31 AM Page 17

 

PROBLEM

CAUSE

CORRECTION

Motor will not

Motor overheated

Allow compressor to cool for

run.

 

approximately 30 minutes so

 

 

 

thermal overload switch will

 

 

 

reset. If unit still does not

 

 

 

start, empty air from tank and

 

 

 

refer to "Thermal overload

 

 

 

protector cuts out

 

 

 

repeatedly" information.

 

 

Fuse blown, circuit breaker

Check fuse box for blown

 

 

tripped.

fuse and replace as

 

 

 

necessary. Reset circuit

 

 

 

breaker. Do not use a fuse or

 

 

 

circuit breaker with higher

 

 

 

rating than that specified for

 

 

 

your particular branch circuit.

 

 

 

Check for proper fuse. You

 

 

 

should use a time delay fuse.

 

 

 

Check for low voltage

 

 

 

problem.

 

 

 

Check the extension cord.

 

 

 

Disconnect the other

 

 

 

electrical appliances from

 

 

 

circuit or operate the

 

 

 

compressor on its own

 

 

 

branch circuit.

 

 

Extension cord is wrong

Check the extension cord.

 

 

length or gauge.

 

 

 

 

Faulty motor.

Have checked by a Trained

 

 

 

Service Technician.

 

 

 

 

 

Other

 

Contact a B&D sevice facility.

 

 

 

 

 

17

Page 17
Image 17
Black & Decker 641915-00, FSCP200 instruction manual Problem Cause Correction