birth defects or other reproductive harm. Some examples of these chemicals are:
• compounds in fertilizers
• compounds in insecticides, herbicides and pesticides
• arsenic and chromium from chemically treated lumber To reduce your exposure to these chemicals, wear approved safety equipment such as dust masks that are specially designed to filter out microscopic particles.
SAVEWARNINGTHESE: INSTRUCTIONS
Fire hazard. Do not store or carry
battery so that metal objects can contact exposed battery terminals. For example, do not place battery in aprons, pockets, tool boxes, product kit boxes, drawers, etc., with loose nails, screws, keys, etc. Transporting batteries can possibly cause fires if the battery terminals inadvertently come in contact with conductive materials such as keys, coins, hand tools and the like. The US Department of Transportation Hazardous Material Regulations (HMR) actually prohibit transporting batteries in commerce or on airplanes (i.e., packed in suitcases and
BATTERY CAP INFORMATION
Battery Cap
Battery storage and carrying caps are provided for use whenever the battery is out of the tool or charger.
Remove cap before placing battery in charger or tool.
Extension Cord
Make sure your extension cord is in good condition. When using an extension cord be sure it is heavy enough to carry the current your product will draw. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating. The following table shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
|
| 120V | Minimum Gauge for Cord Sets |
|
| ||||
|
|
|
| ||||||
|
| Volts | Total Length of Cord in Feet |
|
| ||||
|
| 240V |
|
| |||||
|
| More Not more | American Wire Gauge |
|
| ||||
|
| Ampere Rating |
|
|
|
| |||
|
| Than Than |
|
|
|
|
| ||
|
| 0 | - | 6 | 18 | 16 | 16 | 14 |
|
|
| 6 | - | 10 | 18 | 16 | 14 | 12 |
|
|
| 10 | - | 12 | 16 | 16 | 14 | 12 |
|
Double |
| 12 | - | 16 | 14 | 12 | Not Recommended |
| |
| Insulation |
|
|
|
|
| |||
|
|
|
|
|
| ||||
Double insulated tools are constructed throughout with two | |||||||||
separate layers of electrical insulation or one double thickness | |||||||||
of insulation between you and the toolʼs electrical system. | |||||||||
Tools built with this insulation system are not intended to be | |||||||||
grounded. As a result, your tool is equipped with a two prong | |||||||||
plug which permits you to use extension cords without concern | |||||||||
for maintaining a ground connection. NOTE: Double insulation does | |||||||||
not take the place of normal safety precautions when operating this | |||||||||
tool. The insulation system is for added protection against injury | |||||||||
resulting from a possible electrical insulation failure within the tool. | |||||||||
REPLACEMENT PARTS:When servicing all tools, USE IDENTICAL | |||||||||
REPLACEMENT PARTS. Repair or replace damaged cords. |
4