Black Box LES401A, LES402A Appendix C RS-485 Connections, Appendix C. RS-485 Connections, Page

Models: LES402A LES401A LES404A 1-, 2-, and 4-Port Industrial Ethernet Serial Servers

1 64
Download 64 pages 53.01 Kb
Page 58
Image 58
Appendix C: RS-485 Connections

Appendix C: RS-485 Connections

Appendix C. RS-485 Connections

C.1 1-, 2-, or 4-Port Serial Server DB9 Pinout in RS-485H (Two-Wire, Half-Duplex) Mode

Figure C-1. DB9 male connector.

Table C-1. DB9 pinout in RS-485H mode.

RS-485 Signal Name

Direction

RS-485

DB9 M Pin

 

 

 

 

Data B (+)

In/Out

DATA B (+)

3

 

 

 

 

Data A (-)

In/Out

DATA A (-)

4

 

 

 

 

Signal Ground

GND

5

 

 

 

 

C.2 1-, 2-, or 4-Port Serial Server DB9 Pinout in RS-485F (Four-Wire, Full-Duplex) Mode

Figure C-2. DB9 male connector.

Table C-2. DB9 pinout in RS-485F mode.

RS-232 Signal Name

Direction

RS-422

DB9 M Pin

 

 

 

 

Receive Data A (-)

In

RXDA (-)

1

 

 

 

 

Receive Data B (+)

In

RXDB (+)

2

 

 

 

 

Transmit Data B (+)

Out

TXDB (+)

3

 

 

 

 

Transmit Data A (-)

Out

TXDA (-)

4

 

 

 

 

Signal Ground

GND

5

 

 

 

 

Clear To Send A (-)

In

CTSA (-)

6

 

 

 

 

Clear To Send B (+)

In

CTSB (+)

7

 

 

 

 

Request To Send B (+)

Out

RTSB (+)

8

 

 

 

 

Request To Send A (-)

Out

RTSA (-)

9

 

 

 

 

NOTE: Some RS-485 devices are marked opposite the RS-485 standard, which defines the Data B line as positive relative to Data A during a Mark state before enabling the transmitter, and after transmitting before tri-stating. If an RS-485 device does not respond, try swapping the Data B and Data A lines.

Page 58

724-746-5500 blackbox.com

Page 58
Image 58
Black Box LES401A, LES402A, LES404A manual Appendix C RS-485 Connections, Appendix C. RS-485 Connections, Page