BLADE OS 5.1 Release Notes
Chassis Internal Network
BLADEOS 5.1 now supports BladeCenter Chassis Internal Network (CIN). CIN provides internal connectivity between blade server ports and the internal Advanced Management Module (AMM) port. This allows blade server users to access the AMM via CLI,
BC-S Chassis Support
BLADEOS 5.1 supports the BladeCenter
Port link information (/info/link) for switches installed in bay 1 and bay 2:
Alias | Port | Speed | Duplex | Flow Ctrl | Link | |
INT1A | 1 | 1000 | full | yes | yes | up |
INT1B | 2 | 1000 | full | yes | yes | up |
INT2A | 3 | 1000 | full | yes | yes | up |
INT2B | 4 | 1000 | full | yes | yes | up |
INT3A | 5 | 1000 | full | yes | yes | down |
INT3B | 6 | 1000 | full | yes | yes | up |
INT4A | 7 | 1000 | full | yes | yes | up |
INT4B | 8 | 1000 | full | yes | yes | up |
INT5A | 9 | 1000 | full | yes | yes | up |
INT5B | 10 | 1000 | full | yes | yes | up |
INT6A | 11 | 1000 | full | yes | yes | up |
INT6B | 12 | 1000 | full | yes | yes | up |
SMGT1 | 13 | 1000 | full | yes | yes | up |
SMGT2 | 14 | 1000 | full | yes | yes | up |
MGT1 | 15 | 100 | full | yes | yes | up |
EXT1 | 17 | 10000 | any | yes | yes | up |
EXT2 | 18 | 10000 | any | yes | yes | up |
EXT3 | 19 | 10000 | any | yes | yes | up |
EXT4 | 20 | 1000 | any | yes | yes | up |
EXT5 | 21 | 1000 | any | yes | yes | up |
EXT6 | 22 | 1000 | any | yes | yes | up |
EXT7 | 23 | 1000 | any | yes | yes | up |
EXT8 | 24 | 1000 | any | yes | yes | up |
EXT9 | 25 | 1000 | any | yes | yes | up |
|
|
|
|
|
|
|
16 | BMD00098, December 2009 |