BLADE OS 5.1 Release Notes
Known issues
The following are known issues for BLADEOS 5.1 on the 1/10Gb Uplink Ethernet Switch Module.
Access Control Lists
When an Access Control List (ACL) is installed on two different ports, only one statistics counter will be available. The GbESM does not support two different statistics counter for one ACL installed on two different ports.
The ACL filters for TCP/UDP work properly only on packets that do not have IP options.
When configuring an ACL to set 802.1p priority for
Although the management port can be configured for port filtering option, actual port filtering will not occur, because the system filters out the management VLAN.
IGMP Relay
When having joins from multiple VLANs, and the multicast data transmitter is on a VLAN that did not receive any joins, multicast data is routed only if the flood option is disabled using the
/cfg/l3/igmp/adv/flood d command.
If an IGMP v2 joins an IGMP group on the same port where an IGMP v1 join has already been issued, the software will default to the IGMP v1 timeout value.
Interoperability with Older Hubs
The
NETGEAR FE104 100 hub
SBS
3Com Linkbuilder FMS100 Hub 3C250 TX/I
3Com SuperStack II 100TX
Nortel Baystack 204 Hub
If the GbESM is connected to an Alteon Application Switch which requires a link speed of 100 Mbps