| Maintenance | |
|
|
|
|
|
|
|
|
|
| Troubleshooting Guide | |
|
|
|
|
|
|
|
|
|
|
|
|
|
| POSSIBLE CAUSE(S) |
| SUGGESTED REMEDY |
|
|
|
|
|
| |
| SYMPTOM: Product dried out |
|
|
| |
|
|
|
|
|
|
| S | Oven temperature too low | S | Increase cook temperature |
|
| S | Not using enough water in the mix | S | Increase water in product mix |
|
| S | Thermostat out of calibration | S | * |
|
| S | Faulty flue (strong direct vent) | S | * |
|
|
|
|
|
| |
| SYMPTOM: Extended baking times |
|
|
| |
|
|
|
|
|
|
| S | Temperature setting too low | S | Increase cook time |
|
| S | Low gas pressure | S | * |
|
| S | Strong ventilation | S | * |
|
| S | Excessive door openings | S | Do not open door unnecessarily |
|
|
|
|
| ||
| *Denotes remedy is a difficult operation and should be performed by qualified personnel only. It is recommended, however, that |
| |||
| All repairs and/or adjustments be done by your local Blodgett service agency and not by the owner/operator. Blodgett cannot as- |
| |||
| sume responsibility for damage as a result of servicing done by unqualified personnel. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
11