OPERATION (continued)

OPERATION (continued)

B. PROGRAM BREW VOLUMES

Each BREW VOLUME SELECT KEY is individually

programmable.

 

Keys may be programmed for pulse brewing to optimize

 

contact times and extraction rates, or to minimize overflowing

 

the brew chamber when using large amounts of grounds.

 

Up to 10 pulses may be programmed. Each pulse delay is

 

fixed at 15 seconds.

1.

Place an empty airpot under the brew head. Install the brew

 

chamber (without filter) under the brew head

2.

Press and hold BREW key until beep sounds and the indicator

 

lights flash.

3.

Press and release the VOLUME SELECT KEY to be programmed.

Fig. 5 Program Volumes

Water will begin to flow into the airpot. When the desired water

level is reached, press the key again to stop the water flow.

 

For pulse brew:

a.Press the key to start the water flow.

b.Press the key again to stop the flow after the time desired for the first pulse.

c.Press the key again to resume water flow.

d.Repeat until desired total delivered volume is reached.

NOTE: Water flow can be stopped and restarted up to 10 times per brew. The delay between pulses is fixed at 15 seconds.

4.Press the BREW KEY to enter these settings into memory and resume normal operation.

5.Run a normal brew with filter and grounds to verify settings.

Repeat steps 1 through 4 to program the other VOLUME SELECT KEY, or to revise existing settings.