SERVICING INSTRUCTIONS (continued)
REPLACE SOLENOID
Symptom: Brewer will not flow water; or, brewer drips continuously from brew head.
NOTE: Wrench p/n 86660 is designed to allow easy removal of flare nuts from the water inlet fitting
IMPORTANT:
Remove water supply flare fitting:
a.Slide the 5/8" end of the wrench over the flats on the inlet fitting of the valve.
b.Hold the wrench to prevent the inlet fitting from turning while installing or removing the inlet water supply flare nut.
Remove fill tubing: Disconnect wiring.
Remove two screws holding solenoid to access door. Reassemble in reverse order.
CLEAN SOLENOID SCREEN
Symptom: Automatic brewer will not flow water.
Disconnect brewer from electric power. Turn OFF and disconnect water supply from brewer inlet fitting.
Unscrew water inlet fitting from solenoid.
Using
Reinsert screen in solenoid. Be careful to maintain correct orientation. (The OPEN END of the screen goes in FIRST.)
Reassemble in reverse order.
Fig. 10 Wrench #86660
Fig. 11 Clean Strainer Screen
15