Bloomfield 0420 owner manual Operation, Water Flow Diagram, A. Start-Up

Models: 0420

1 24
Download 24 pages 40.96 Kb
Page 9
Image 9
OPERATION

OPERATION

Fig. 4 Water Flow Diagram

A.START-UP

For initial start-up, or if the brewer has not been used for an extended period of time:

Be sure spray disk and brew gasket are properly installed in the brew head.

Be sure the water supply is properly connected and the water supply valve is turned ON and that TANK HEATER SWITCH is OFF before connecting brewer to electric power.

Be sure the WATER TANK IS FILLED.

IMPORTANT: Fill the water tank before energizing this brewer.

1.Connect brewer to electric power. Brewer will begin filling. When solenoid closes, tank is full.

2.Place an empty container in the hot water well. Press the HOT WATER DISPENSER BUTTON and dispense one cup of water. Tank should refill. Discard water.

3.Press TANK HEATER SWITCH to ON.

4.When READY light glows, brewer is ready to use.

IMPORTANT:

TANK MUST BE FULL OF WATER BEFORE CONNECTING BREWER TO ELECTRIC POWER.

Heating elements will be damaged if allowed to operate without being fully submerged in water. Damage caused by operating the brewer without water in the tank is NOT COVERED BY WARRANTY.

See page 8 for setting delivered water volumes for VOLUME SELECTION KEYS.

7

Page 9
Image 9
Bloomfield 0420 owner manual Operation, Water Flow Diagram, A. Start-Up