Bloomfield 0420 owner manual SERVICING INSTRUCTIONS continued, Remove Tank Lid Assembly

Models: 0420

1 24
Download 24 pages 40.96 Kb
Page 16
Image 16
REMOVE TANK LID ASSEMBLY

SERVICING INSTRUCTIONS (continued)

IMPORTANT:

Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN.

IMPORTANT:

When mounting thermostat, be sure to insert sensing bulb to the bottom of the bulb well. Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary.

IMPORTANT:

When replacing heating element, also replace seal gaskets.

REMOVE TANK LID ASSEMBLY

Disconnect brewer from electric power. Turn OFF water supply. Remove top panel. Pull vent tube, inlet elbow, outlet elbow and water level probe out of basin pan.

Disconnect all wiring from thermostat, hi-limit, and heating element.

Loosen nuts on tank hold-down strap. Remove hold-down strap by sliding short slotted end off of locking stud and lifting it off. Remove cover assembly by lifting it straight up.

Reassemble in reverse order.

REPLACE THERMOSTAT (COTHERM)

Disconnect brewer from electric power. Turn OFF water supply. Remove top panel.

Disconnect all wiring from thermostat only. Loosen and free jam nut from pass-thru fitting securing temperature sensing bulb. Remove two screws holding thermostat to bracket.

Lift out thermostat, sensing bulb and thermostat gasket.

Reassemble in reverse order. BE SURE the bulb well is fully seated in the tank fitting, and that the temperature sensing bulb is inserted to the very bottom of the bulb well.

REPLACE HEATING ELEMENT

Remove tank lid assembly per above.

Remove two hex nuts holding element to cover. Pull element from mounting holes.

Reassemble in reverse order.