SERVICING INSTRUCTIONS (continued)
IMPORTANT:
Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT
IMPORTANT:
When mounting thermostat, be sure to insert sensing bulb to the bottom of the bulb well. Tighten capillary lock nut only enough to ensure no water leakage. Excessive tightening is not necessary.
IMPORTANT:
When replacing heating element, also replace seal gaskets.
REMOVE TANK LID ASSEMBLY
Disconnect brewer from electric power. Turn OFF water supply. Remove top panel. Pull vent tube, inlet elbow, outlet elbow and water level probe out of basin pan.
Disconnect all wiring from thermostat,
Loosen nuts on tank
Reassemble in reverse order.
REPLACE THERMOSTAT (COTHERM)
Disconnect brewer from electric power. Turn OFF water supply. Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free jam nut from
Lift out thermostat, sensing bulb and thermostat gasket.
Reassemble in reverse order. BE SURE the bulb well is fully seated in the tank fitting, and that the temperature sensing bulb is inserted to the very bottom of the bulb well.
REPLACE HEATING ELEMENT
Remove tank lid assembly per above.
Remove two hex nuts holding element to cover. Pull element from mounting holes.
Reassemble in reverse order.
14