page no.

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

11

 

 

 

Cleaning and Care (continued)

Cleaning Surfaces

1.Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.

2.For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush.

3.Rinse clean with water.

4.Allow to air dry.

Cleaning Main Burner

1.Turn gas “OFF” at the control knobs and natural gas line valve to “CLOSED”.

2.Remove cooking grid and heat plates.

3.Remove burner by removing the fasteners securing the burner to the grill bottom.

4.Lift burner up and away from gas valve orifice.

5.Disconnect wire from spark electrode.

6.Clean inlet (venturi) of burner with small bottle brush or compressed air.

7.Remove all food residue and dirt on burner surface.

8.Clean any clogged ports with a stiff wire (such as an opened paper clip)

9.Inspect burner for any damage (cracks or holes). If damage is found, replace with new burner.

10.Reinstall burner, check to insure that gas valve orifice is correctly positioned inside burner inlet (venturi). Also check position of spark electrode.

11.Replace heat plate and cooking grid.

12.Perform leak test.

Cleaning Side Burner

Figure 111

Burner Flame Conditions

Use this chart check to see if your

burners need to be cleaned.

-2 in. /

- 50.8 mm

1

25.4

-2 in. /

- 50.8 mm

1

25.4

Normal: Soft blue flames with yellow tips between 1 in. - 2 in. hight.

Needs Cleaning: Noisy with hard blue flames.

Has to be cleaned: Wavy with yellow flames.

Product Registration

For faster warranty service, please register your product immediately at www.bluerhino.com or call 1.800.762.1142.

Limited Warranty

Blue Rhino Global Sourcing, Inc (“Vendor”) warrants to the original retail purchaser of this product, and to no other person, that if this product is assembled and operated in accordance with the printed instructions accompanying it, then for a period of one (1) year from the date of purchase, all parts in such product shall be free from defects in material and workmanship. Vendor may require reasonable proof of your date of purchase. Therefore, you should retain your sales slip or invoice. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service and which Vendor shall determine in its reasonable discretion upon examination to be defective. Before returning any parts, you should contact Vendor’s Customer Service Department using the contact information listed below. If Vendor confirms, after examination, a defect covered by this Limited Warranty in any returned part, and if Vendor approves the claim, Vendor will replace such defective part without charge. If you return defective parts, transportation charges must be prepaid by you. Vendor will return replacement parts to the original retail purchaser, freight or postage prepaid.

This Limited Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance or service by you or any third party, or failure to perform normal and routine maintenance on the product as set out in this owner’s manual. In addition, the Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.

This Limited Warranty is in lieu of all other express warranties. Vendor disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors, including the warranty of merchantability or the warranty of fitness for a particular purpose.

VENDOR ALSO DISCLAIMS AND ANY ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. VENDOR SHALL NO LIABILITY TO PURCHASER OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. Vendor further disclaims any implied or express warranty of, and assumes no responsibility for, defects in workmanship caused by third parties.

1.Turn gas “OFF” at the control knobs and natural gas line valve to “CLOSED”.

2.Remove side burner grid.

3.Remove burner by removing the screws securing the burner to the side shelf.

4.Lift burner up and away from gas valve orifice.

5.Clean inlet (venturi) of burner with small bottle brush or compressed air.

6.Remove all food residue and dirt on burner surface.

7.Clean any clogged ports with a stiff wire (such as an opened paper clip)

8.Inspect burner for any damage (cracks or holes). If damage is found, replace with new burner.

9.Reinstall burner, check to insure that gas valve orifice is correctly positioned inside burner inlet (venturi). Also check position of spark electrode.

10.Replace cooking grid.

11.Perform leak test.

This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some jurisdictions do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to everyone.

Vendor does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on Vendor.

Blue Rhino Global Sourcing, Inc Winston-Salem, North Carolina 27105 USA 1.800.762.1142

Page 11
Image 11
Blue Rhino GBC956W1NG-C owner manual Product Registration Limited Warranty, Burner Flame Conditions, Cleaning Surfaces