INTEGRUS Installation and User Instructions Connecting to an Integrus transmitter | en 9 |
|
|
3.1.1Maximum cable length for connecting interpreters desks LBB 3222/04
The maximum length of the cables to connect the interpreters desks to the Integrus transmitter depends on the number of interpreters desks. A leader cable connects the first interpreters desk to the transmitter. An extension cable may be needed between the inter- preters desks. The table below shows the maximum extension cable length (additional to the standard 3 m cable) that can be used with different numbers of inter- preters desks.
Number of interpreters desks LBB 3222/04 |
| 2 | 4 | 6 | 8 | 10 | 12 |
|
|
|
|
|
|
|
|
Additional leader cable length between | meter | 100 | 50 | 35 | 15 | 5 | 0 |
first interpreter desk and transmitter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Additional extension cable lengths | meter | 34 | 8 | 2.9 | 2.4 | 1.8 | 1 |
between interpreters desks |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Number of interpreters desks LBB 3222/04 |
| 2 | 4 | 6 | 8 | 10 | 12 |
|
|
|
|
|
|
|
|
Additional leader cable length between | feet | 328 | 164 | 115 | 49 | 16 | 0 |
first interpreter desk and transmitter |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Additional extension cable lengths | feet | 112 | 26 | 9.5 | 7.9 | 6.0 | 3.3 |
between interpreters desks |
|
|
|
|
|
|
|
Bosch Security Systems