Note: The unit will work at lower supply voltages but the following changeswill apply:

Maximum output

15kW at 220V

22.5kW at 220V

 

13kW at 208V

20kW at 208V

Temperature control range

87°F to 116°F at 220V

87°F to 116°F at 220V

 

82°F to 108°F at 208V

82°F to 108°F at 208V

Maximum flow rate

84% of maximum at 220V

84% of maximum at 220V

(refer to Graph 1, Page 8)

75% of maximum at 208V

75% of maximum at 208V

WARNING

Always switch off the electricity supply to the unit before you remove the cover.

If you have a problem...

Service should only be performed by qualified personnel

 

Symptom

Cause

 

What to do

 

 

 

 

 

 

 

 

Electricity not on or one of the

 

Check electricity supply.

 

 

supplies has failed.

 

 

 

 

 

 

 

 

The water supply is connected

 

Reconnect the water supply to the inlet

 

 

to the outlet of the unit.

 

of the unit (marked blue).

 

 

 

 

Turn off the power, open the unit and

 

 

One or more of the heater

 

reset by pushing the button(s) on the

 

 

module cut-outs has tripped.

 

top of the heater module(s). Establish

 

Cold water only–

 

 

and fix the cause of the overheating.

 

 

 

Test by turning cold water supply off to

 

neon light off.

 

 

heater, then open hot water faucet(s).

 

 

Plumbing crossover.

 

No pressurized water flow should be

 

 

 

evident. If it is evident, then that

 

 

 

 

 

 

 

 

plumbing crossover needs to be

 

 

 

 

corrected for the heater to operate.

 

 

 

 

Turn off the power, open the unit and

 

 

The flow transducer is not

 

observe if the flow transducer “spins”

 

 

working.

 

when the water is turned on. If not,

 

 

 

 

contact BBT toll free at 866-330-2729.

 

 

 

 

 

 

 

 

Water flow is too high.

 

Adjust the water flow (see Graph 1

 

 

 

 

on Page 8).

 

 

 

 

 

 

 

 

One of the power supplies is not

 

Check the supply voltages to the

 

 

 

on.

 

heater and rectify if necessary.

 

 

 

 

 

This is likely an issue with the power

 

 

Water too cold–

The power supply voltage has

 

supply. Compensate for this by

 

 

dropped.

 

increasing the temperature setting

 

 

neon light on

 

 

 

 

 

(turn dial clockwise).

 

 

 

 

 

 

 

 

Temperature dial is turned too

 

Turn the temperature control dial

 

 

 

low.

 

clockwise.

 

 

 

The inlet water temperature has

 

Turn temperature knob up or reduce

 

 

 

 

the flow rate according to Graph 1

 

 

 

dropped.

 

 

 

 

 

on Page 8.

 

 

 

 

 

 