WARNING
The unit must only be installed in the orientation shown in Diagram 1, i.e., mounted in a vertical position with the water fittings located at the bottom of the unit. Under no circumstances should the unit be
mounted differently.
•If being used in a public place, position the unit out of easy reach to discourage vandalism.
•Mount the unit onto a flat section of wall, well away from any potential splashes of water or spray.
•Position the unit upright with all plumbing and electrical connections at the bottom of the unit.
Mounting on the wall
•Undo the retaining screws on the front cover and take the cover off the unit. Hold the back plate in position against the wall and mark the four mounting holes.
•Drill the holes and secure the unit using the four wood screws supplied or an appropriate alternative method.
Plumbing the unit
WARNING
Do not install a
Fitting the pipes
•The unit should be connected directly to the main cold water supply and not to
•It is recommended that you use ¾ inch or ½ inch copper or
•Use Teflon tape for sealing pipe threads. Do NOT use pipe dope.
•Remember to keep the hot water pipe runs as short as possible.
•After the unit has been plumbed, and before you wire it, flush it with water to remove any debris or loose particles. Failure to do so may make the unit inoperable.
Connecting the unit to the pipes
•The inlet and outlet connections are clearly marked on the unit. They each have a ¾ inch NPT connector.
•Install a ball valve in the cold water line. This valve can be used to turn off the water supply to the unit if it needs servicing, or to reduce the water flow if it is too high.
DISCLAIMER
As a condition of installing this product in the Commonwealth of Massachusetts a pressure relief valve shall be installed on the cold water side, by a licensed plumber MGL 142 Section 19 Approval number:
Wiring to the unit in the United States of America
WARNING
The unit must be installed by a qualified electrician, in accordance with the current version of the National Electrical Code. The unit must be grounded.
4