Installation Instructions
3. Before Installation
WARNING
Check the Gas
•Check that the data plate (located inside of front cover) or a temporary label (located on the front cover)
indicates the correct type of gas. | For NG Gas |
| |||
• Check that the gas supply line is sized for |
|
|
|
| |
178 MJ/hr for this unit. |
|
|
|
| |
• DO NOT OPERATE WITH ANY OTHER GAS TYPE. |
| MODEL BC2600RA |
| ||
|
|
| GAS TYPE | : NG | |
Check the Power |
|
| GAS CONSUMPTION | : 178MJ/hr | |
|
| HEAT OUTPUT | : 45.7kW | ||
• The power supply required is 240/230VAC, at 50Hz. |
| ELECTRICAL RATING | : AC240/230V 50Hz | ||
| RATED POWER | : 56.0W | |||
Using the incorrect voltage may result in fire or |
| HOT WATER SUPPLY CAPACITY | : 26L/min RAISED 25°C | ||
|
| TEST POINT | : MAX : 0.73kPa | ||
electric shock. |
|
| |||
|
|
| : MIN : 0.18kPa | ||
|
|
|
| ||
|
|
| GAS SUPPLY PRESSURE | MAX 3 0kP |
Warning labels
• Located on the right side of the casing
Use Extreme Caution if Using With a Solar Pre-Heater
•A solar transfer valve must be installed with all solar applications when using Bosch Eco 26+.
•Solar systems installed without a solar transfer valve will void all Bosch warranty.
CAUTION
Do Not Use Equipment for Purposes Other Than Those Specified
•Do not use for other than increasing the temperature of the water supply, as unexpected accidents may occur as a result.
Check Water Supply Quality
•If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in order to ensure full warranty coverage.