Installation Instructions

3. Before Installation

WARNING

Check the Gas

Check that the data plate (located inside of front cover) or a temporary label (located on the front cover)

indicates the correct type of gas.

For NG Gas

 

• Check that the gas supply line is sized for

 

 

 

 

178 MJ/hr for this unit.

 

 

 

 

• DO NOT OPERATE WITH ANY OTHER GAS TYPE.

 

MODEL BC2600RA

 

 

 

 

GAS TYPE

: NG

Check the Power

 

 

GAS CONSUMPTION

: 178MJ/hr

 

 

HEAT OUTPUT

: 45.7kW

• The power supply required is 240/230VAC, at 50Hz.

 

ELECTRICAL RATING

: AC240/230V 50Hz

 

RATED POWER

: 56.0W

Using the incorrect voltage may result in fire or

 

HOT WATER SUPPLY CAPACITY

: 26L/min RAISED 25°C

 

 

TEST POINT

: MAX : 0.73kPa

electric shock.

 

 

 

 

 

: MIN : 0.18kPa

 

 

 

 

 

 

 

GAS SUPPLY PRESSURE

MAX 3 0kP

Warning labels

• Located on the right side of the casing -PLEASE READ THESE LABELS CAREFULLY!

Use Extreme Caution if Using With a Solar Pre-Heater

A solar transfer valve must be installed with all solar applications when using Bosch Eco 26+.

Solar systems installed without a solar transfer valve will void all Bosch warranty.

CAUTION

Do Not Use Equipment for Purposes Other Than Those Specified

Do not use for other than increasing the temperature of the water supply, as unexpected accidents may occur as a result.

Check Water Supply Quality

If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in order to ensure full warranty coverage.

4

Page 4
Image 4
Bosch Appliances BC2600RA Before Installation, Check the Gas, Use Extreme Caution if Using With a Solar Pre-Heater