Installation Instructions
Connecting Remote Controller Cord to Unit
•Tie the redundant cord outside the water heater. Do not put the extra length inside the water heater.
•The remote controller cord can be extended up to 20m.
•Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to the terminal block.
Remote controller cord
•Use remote controller cord for any extensions.
•Install according to the National Electrical Code and all applicable local codes.
1.Check to make sure that the remote controller cord has plenty of slack in order to reach the external
connection terminal block.
2. Disconnect electrical power to the water heater.
3. Remove the single screw securing the terminal block cover and then remove the cover.
4. Pass the remote controller cord through the wiring throughway and connect the Y terminals at the end of the remote controller cord to the terminal block.
5.Replace the terminal block cover and install the screw previously removed in step 3.
6.Reconnect electrical power to the water heater.
External connection terminal block
Wiring throughway
Remote controller cord
Power cord
15