Output 1 Name O001
Is Off and Ready
Press OK or MENU
The keypad will display the following when the output is off and missing:
Output 1 Name O001
Is Off and Ready
Connection Trouble
Press OK or MENU
The keypad will display the following when the output is ON and OK:
Output 1 Name O001
Is ON and Ready
Press OK or MENU
The keypad will display the following when the output is ON and missing:
Output 1 Name O001
Is ON and Ready
Connection Trouble
Press OK or MENU
4.Press [OK] to save and exit, or press [MENU] to exit without saving.
Outputs > Commands >
Turn Output On/Off | MENU |
This menu allows you to turn outputs that have been programmed by your security company on or off. These outputs can be programmed to control outside lighting, pool pumps, watering systems etc.
Enter programming mode (PIN + MENU) then,
1.Press [MENU] + [4] + [0] + [1].
If a valid PIN is required, the keypad will prompt you to enter your PIN.
2.Use the [↑] and [↓] keys to select the output name that you want to change, then press [OK] to select. Alternatively, you can enter the output number, then press [OK].
3.To toggle the output on or off, use the [ON] and [OFF] keys.
The keypad will display the following when the output is off:
Solution 64 User Guide
Output 1 Name O001
Output is OFF,
To Turn ON,Press ON.
To Go Back Press OK
To turn the output on, press [ON].
The keypad will display the following when the output is on:
Output 1 O001
Output is ON,
To Turn OFF,Press OFF.
To Go Back Press OK
To turn the output off, press [OFF].
4.Press [OK] to save and exit, or press [MENU] to exit without saving.
Outputs > Properties >
Output Name | MENU |
This menu allows you to program the name for each output. Each output name supports up to 16 characters.
Enter programming mode (PIN + MENU) then,
1.Enter [MENU] + [4] + [1] + [0].
A list of different outputs will display on the keypad.
2.Use the [↑] and [↓] keys to select the output name that you want to change, then press [OK] to select. Alternatively, you can enter the output number, then press [OK].
The keypad will display the following:
Output Name O001
Output 1
Press ◄► OK to SAVE
3.Use the [←] and [→] keys to scroll the cursor left and right across the output name text. Use the [↑] and [↓] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.
4.Press [OK] to save and exit, or press [MENU] to exit without saving.
Bosch Security Systems |
| 09/06 |
| BLCC110U | 19 |
|
|