4. Connect Electric

Step 4: Connect Electric

 

Verify that electric to the junction box has been turned off before beginning this step.

General Instructions:

Use copper wire ONLY. Wire size and connections must be suitable for the rating of the appliance per the National Electrical Code requirements or the Canadian Electric Code requirements.

The flexible conduit extending from the oven

should be connected directly to the junction box.

• Do not shorten flexible conduit.

The junction box should be located to allow as

 

much slack as possible between the junction box

Figure 4: Four Wire Connection

and the oven.

Installation

A UL listed conduit connector must be provided at each end of the power supply cable.

The four wire branch circuit connection is preferred, but where local codes permit, a three wire branch circuit connection is also acceptable.

Four Wire Connection (Preferred Method):

1.Connect green ground wire from oven to green (or bare) ground wire in junction box.

2.Connect red wire from oven to red wire in junction box.

3.Connect black wire from oven to black wire in junction box.

4.Connect white wire from oven to white (or gray) neutral wire in junction box.

Three Wire Connection :

Note: The four wire connection is preferred, but where local codes permit, the three wire connection is also acceptable.

1.Connect red wire from oven to red wire in junction box.

2.Connect black wire from oven to black wire in junction box.

3.Connect both green ground wire and white wire from oven to white (or gray) neutral wire in junction box.

Connecting to a 208 V circuit (700 Series):

The oven is pre-wired for connection to 240 V, 60 Hz supply, but can be converted for use with 208 V, 60 Hz supply.

1.Turn power on a breaker.

2.Open oven door (upper oven in double ovens)

3.Press CANCEL.

4.Turn knob clockwise until 6 double beeps sound.

4.Turn knob couonterclockwise until 9 double beeps sound.

5.Press START.

6.Press COOKING MODE.

7.Press START.

Time of day clock appears in display.

Figure 5: Three Wire Connection

Connecting to a 208 V circuit (5000 Series):

The oven is pre-wired for connection to 240 V, 60 Hz supply, but can be converted for use with 208 V, 60 Hz supply.

1.Turn power on a breaker.

2.Press and hold SET CLOCK and TIMER for at least three seconds.

Sele dEG appears in display.

3.Press and hold STOP TIME and TIMER for at least three seconds.

Display is blank.

4.Press and hold COOK TIME and STOP TIME for at least three seconds.

VOLT 240 is displayed.

5.Press SET CLOCK.

6.Press + or - to select appropriate voltage (choose 208 for 208 V connection; choose 240 to 240 V connection).

7.Press SET CLOCK.

8.Press and hold STOP TIME and TIMER for at least three seconds.

Sele dEG appears in display

8.Press and hold SET CLOCK for at least three seconds.

Time of day clock appears in display.

4 • English