Bosch Appliances CC408 Turning Outputs On/Off, Reset Latching Outputs, Testing, 17.2Bell Test

Models: CC408

1 28
Download 28 pages 58.61 Kb
Page 14
Image 14
14. Turning Outputs On/Off

CC408 Operators Guide 14. Turning Outputs On/Off

EN 14

14. Turning Outputs On/Off

This feature only applies if your installer set up an output that can be turned on or off by the codepad. The output programmed by your installer can control a pool pump, outside lighting, and so on. Up to three separate outputs may be programmed.

How to Turn an Output On or Off

1.Enter your Master Code followed by the [5] and

[#] keys (for example, [2 5 8 0 5 #]).

Three beeps sound and the STAY and AWAY indicators flash.

2.Enter the output number (1 to 3) that you wish to turn on or off.

3.Press the [#] key to turn the output on, or press the [*] key to turn the output off.

Three beeps sound if the output is turned on, and two beeps sound if the output is turned off. Repeat Step 2 and Step 3 if you require more than one output to be turned on or off.

4.Press the [#] key to exit this function.

Two beeps sound and the STAY and AWAY indicators go dark.

15. Reset Latching Outputs

This feature only applies if your installer programmed an output to latch (remain on) until you acknowledge the event that occurred.

How To Reset Latching Outputs

Hold down the [7] key until two beeps sound. The output resets.

16. Codepad ID/Buzzer Tone Change

Hold down the [8] key continuously to change the tone of the codepad buzzer. There are 50 different tones, from 1500 Hz to 5000 Hz. If multiple codepads are installed, each codepad can sound a different tone.

If the system is partitioned, the keypad first displays the area to which the keypad is assigned:

ξ Zone 1: Area 1 codepad

ξ Zone 2: Area 2 codepad

ξ Zone 7: master partitioned codepad

17.Testing

There are various functions for testing that your system is operating correctly.

17.1Horn Speaker Test

Press and hold the [1] key until two beeps sound. The horn speaker sounds for 2 seconds.

17.2Bell Test

Press and hold the [2] key until two beeps sound. The bell output operates for 2 seconds.

17.3Strobe Test

1.Press and hold the [3] key until three beeps sound.

The strobe flashes.

2.Press and hold the [3] key until two beeps sound. The strobe stops flashing.

17.4Walk Test Mode

Use Walk Test Mode to test detection devices for proper operation. Every time you test a zone, the codepad sounds one long beep and the horn speaker sounds one short beep to indicate the zone was activated when testing.

1.Enter your four-character Master Code, followed by the [7] and [#] keys (for example,

[2 5 8 0 7 #]).

Three beeps sound, and the STAY and AWAY indicators flash. The codepad beeps once every second while the system is in Walk Test Mode.

2.Activate all zones that require testing.

The codepad sounds one long beep and the horn speaker sounds one short beep every time a zone is faulted (unsealed) and restored.

3.When you finish testing all required zones, press the [#] key to exit this mode.

Two beeps sound, and the STAY and AWAY indicators turn off. The system returns to the disarmed state.

17.5Test Report

This feature only applies if your system reports by telephone. Press and hold the [9] key until two beeps sound. The system sends a Test Report without sounding the sirens.

Bosch Security Systems 5/04 920050O.OG.112