7Troubleshooting

CCS 800 Ultro Installation and Operating Manual

en 17

7Troubleshooting

Temporary no microphone reaction, and no sound or distorted sound from unit loudspeakers

Possible cause Trunk-line overload.

Solution

Reduce load on the trunklines by reducing the number of units, and/or the length of the trunk cables.

Acoustic Feedback

Possible cause

Loudspeaker volume too loud.

Solution

-Reduce gain using volume control for delegate/ chairman unit loudspeakers on CPSU.

-If available, switch on Digital Acoustic Feedback Suppression.

Possible cause

Distance between units too small (microphone to loudspeaker of other units).

Solution

-Increase distance between units.

-If available, switch on Digital Acoustic Feedback Suppression.

Possible cause

Too close to microphone units, when using open headphones.

Solution

-Increase the distance between headphone and microphone or disconnect headphones when not in use.

-If available, switch on Digital Acoustic Feedback Suppression.

Part of system not working

Possible cause

Interrupted trunk-line cabling.

Solution

Check the trunk-line cabling connections between the units and the CPSU, also use the test function on the CPSU.

No sound via delegate/chairman loudspeakers

Possible cause

Insertion switch in wrong position.

Solution

Check if insertion switch at the rear of the CPSU is in position "1".

Possible cause

Volume control position.

Solution

Check if the volume control for delegate/chairman loudspeakers on the CPSU is not in the fully counter clockwise position.

Possible cause

Microphone active or headphone connected.

Note

Units with active microphone or connected headphone(s) have their loudspeakers switched off.