Bosch Appliances manual Mains connection, CCS 800 Ultro Installation and Operating Manual, en

Models: CCS 800 Ultro

1 23
Download 23 pages 48.69 Kb
Page 8
Image 8
5.10 Mains connection

CCS 800 Ultro Installation and Operating Manual

en 10

5.8 Connecting a telephone coupler 5.9 Connecting an equalizer

1

 

 

Telephone Insertion

 

Recorder

Line

 

 

 

In

Gain

Gain

 

Out

 

 

 

 

 

4

 

 

 

2

 

 

3

 

Figure 5.8

1

Recorder

Line

Telephone

Insertion

 

 

 

 

In

Gain

Gain

 

 

Out

 

 

 

 

 

 

 

3

 

 

 

2

 

4

 

 

 

 

Figure 5.9

Connect the telephone coupler (2) to the telephone input and output of the CPSU (1). The telephone coupler is further connected to the telephone wall socket (4) and a telephone (3) for dialing.

A connection to a telephone network must always be made via a telephone coupler that provides adequate isolation between the telephone network (PBX) and the CCS 800 Ultro system. The telephone coupler shall also meet all relevant requirements for this type of communication equipment as imposed by law and/or responsible telecommunication organisations in the country of use.

Caution

Never try to make a direct connection between the telephone network and the CCS 800 Ultro discussion system.

Put the insertion switch (3) in position "0" and connect the cabling (2) of the (mono) equalizer (4) to the insertion input and output of the CPSU (1). Switch (3) must be in position "1" (loop through) if the insertion input/output is not used.

5.10 Mains connection

Trunk in/out

Microphone

Recorder

 

Line

 

Telephone

Insertion

 

 

 

 

1

 

 

 

 

 

 

 

 

In

 

2

 

 

 

 

 

 

 

 

Out

Digital Acoustic

Gain

Gain

 

 

 

 

 

 

Feedback Suppression

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90-260 V~

CCS 800 ULTRO

 

 

 

 

 

 

 

 

 

 

 

 

 

4

1

4

5

6

4

5

6

 

 

 

 

3

2

3

 

7

3

 

7

 

 

 

 

2

3

2

 

8

2

 

8

 

 

 

 

1

4

1

 

9

1

 

9

 

 

 

 

 

 

0

 

10

0

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

5

3

 

4

 

 

 

 

 

 

 

 

 

Figure 5.10

Use the supplied mains cord set (5) to connect the CPSU (1) to the mains supply (2). Press the on/off switch (3) to power up the system, the power on LED (4) will lit.

Bosch Security Systems 2003-06 3922 988 54284

Page 8
Image 8