Ducting Recommenda- tions

Ducting Recommenda- tions

Overall Dimensions

The hood can be ducted to the outside or used with a recirculation unit. The recir- culation unit is available from your dealer.

For the most efficient air flow exhaust, use a straight duct run or as few elbows as possible.

Do not use flex ducting. Always use metal ductwork with minimum diameter of 6” (150 mm). A transition is necessary to connect to larger diameter ductwork or to square ductwork.

COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house.

Always install a metal vent cover where the ductwork exits the house.

Make-Up Air: Local building codes may require the use of make-up air systems when using ducted ventilation systems greater than specified CFM of air move- ment. The specified CFM varies from locale to locale. Consult your HVAC profes- sional for specific requirements in your area.

The overall dimensions are:

Width: 30” (760 mm) / 35 1/2" (900 mm)

Depth: 20" (500 mm)

Height: 30 1/2 -46 1/2” (775-1187 mm), depending on chimney extension

30 1/2 - 46 1/2"

(775 - 1187 mm)

20"

 

 

1/2"

 

35

 

/

 

mm)

(500

 

30

 

 

mm)

 

900

 

/

 

 

(760

 

 

 

 

 

 

Figure 1: Overall Dimensions

Mounting Requirements The hood must be mounted through the back wall. It cannot be mounted from above. See “General Information” on page 2 for suggestions for determining hood height.

For safety purposes, the wall must be able to support three times the weight of the hood. See “Minimum Weight Requirements” on page 4 for the minimum amount

English 3