38 en Subsystem Maintenance and Upgrading | RAID Subsystem |
|
|
Fig. 6.6 PSU Parts Identification
Fig. 6.7 Removing the PSU Retention Screw
2.Once the power switch has been turned off, remove the power cable that connects the RAID subsystem to the main power. The power cable socket is found on the
3.After the power cable has been removed from the socket, remove the retention screw at the top
4.Remove the PSU module. Push the extraction lever at the back of the PSU module down- wards. This will dislodge the PSU module from the subsystem. Once dislodged gently pull the PSU module out of the subsystem. (See Figure 6.8).
Fig. 6.8 Removing the PSU Module
5.Remove the cooling module. To do this, push the clips on either side of the cooling mod- ule rear panel together. Then gently pull the cooling module out of the lower level of the PSU bracket. (See Figure 6.9)
F.01U.027.798 V1 2006.06 | Bosch Security Systems |