26 en Subsystem MonitoringRAID Subsystem DVA-12T Installation Manual

 

Upper Threshold

Lower Threshold

 

 

 

+3.3V

+3.6V

+2.9V

 

 

 

+5V

+5.5V

+4.5V

 

 

 

+12V

+13.2V

+10.8V

 

 

 

CPU Temperature

95ºC

5ºC

 

 

 

Controller Board

80ºC

5ºC

Temperature

 

 

 

 

 

Enclosure Ambient

40ºC

0ºC

Temperature

 

 

 

 

 

Table 4.6 Default Threshold Values

 

The thresholds in Table 4.6 are default threshold values and may be changed.

4.3.2

Failed Devices

i

If any of the following components fails, the audible alarm will be triggered:

RAID controller module

Cooling fan modules

PSU modules

BBU module

Hard disk drives

NOTICE!

When the temperature exceeds a preset threshold, the controller’s charger circuits will stop charging. You will then receive a message that says “Thermal Shutdown/Enter Sleep Mode.” When the temperature falls back within normal range, the battery will resume charging.

4.4I2C Monitoring

The operating status of PSU and cooling fan modules are collected through an I2C serial bus. If either of these modules fails, the failure will be detected and you will be notified through the various methods described above.